Ifthehasbeenconfiguredbyadistributor,
thefollowinglimitsarestored.
FLY dat
Enginetype618UL:
NOTE:
Donotruntheengineabovetheselimits
.
Please,payattentiontothelimitsasspecified
intheOperator'smanualfortheengine.
LIMITS
WarningandAlarm
Enginetype912ULDCDI:
Display Unit Warn limit Alarm limit
field
Engine speed rpm 7000 7300
Exhaust gas temp. °C 650 680
Cylinder head temp. °C 165 180
Coolant temperature °C 85 95
Ambient air tepmperature °C 40 50
Display Unit Warn limit Alarm limit
field
Engine speed rpm 5800 6000
Exhaust gas temp. °C 880 900
Cylinder head temp. °C 135 150
Oil temperature °C 130 145
Oil pressure max. bar 6,0 8,0
Oil pressure min. bar 2,0 1,0
WarningandAlarm